Search Wiki:

Description

The group header of a data grouping is not printed at the top of each page as expected after you install Microsoft Visual FoxPro 9.0 Service Pack 2.

Symptoms

Consider the following scenario:
  • You have installed Microsoft Visual FoxPro 9.0 Service Pack 2 on a computer.
  • You have a report that contains a data grouping.
  • You select the Reprint group header on each page option for the data grouping.
  • You run the report.
  • The details for the data grouping end near the bottom of a page. This causes the data group footer to be printed at the top of the next page.

In this scenario, the header of the next data group and the footer of the current data group are interleaved at the top of the next page as follows:
  • The data group header of the next data group
  • The data group footer of the current data group
  • The details for the next data group

However, you expect that the data group headers and footers should print at the top of the next page as follows:
  • The data group header of the current data group
  • The data group footer of the current data group
  • The data group header of the next data group
  • The details for the next data group

Resolution

Hotfix information
A supported hotfix is now available from Microsoft. However, it is intended to correct only the problem that this article describes. Apply it only to systems that are experiencing this specific problem.

Prerequisites
You must have Visual FoxPro 9.0 Service Pack 2 installed to apply this hotfix.

Restart requirement
You do not have to restart the computer after you apply this hotfix.

Hotfix replacement information
This hotfix does not replace any other hotfixes.

Additional Information
http://support.microsoft.com/kb/968409

Other Hotfixes

Search for all other publicly available Visual FoxPro Hotfixes:
http://code.msdn.microsoft.com/Project/ProjectDirectory.aspx?TagName=Hotfix&ProjectSearchText=FoxPro